Two sample MR report
Telomere_length against rfMRI connectivity (ICA25 edge 193)
Date: 22 April, 2022
Results from two sample MR:
| method |
nsnp |
b |
se |
pval |
| MR Egger |
23 |
0.0387093 |
0.1019964 |
0.7081154 |
| Weighted median |
23 |
0.0526315 |
0.0563852 |
0.3505988 |
| Inverse variance weighted |
23 |
0.0189350 |
0.0390155 |
0.6274491 |
| Simple mode |
23 |
0.0432398 |
0.0993491 |
0.6676345 |
| Weighted mode |
23 |
0.0461957 |
0.0657036 |
0.4893726 |
Heterogeneity tests
| method |
Q |
Q_df |
Q_pval |
| MR Egger |
21.92542 |
21 |
0.4038184 |
| Inverse variance weighted |
21.97174 |
22 |
0.4615765 |
Test for directional horizontal pleiotropy
| egger_intercept |
se |
pval |
| -0.0012143 |
0.0057653 |
0.8352087 |
Test that the exposure is upstream of the outcome
| snp_r2.exposure |
snp_r2.outcome |
correct_causal_direction |
steiger_pval |
| 0.0357937 |
0.0006729 |
TRUE |
0 |
Note - R2 values are approximate
Forest plot of single SNP MR

Comparison of results using different MR methods

Funnel plot

Leave-one-out sensitivity analysis