Two sample MR report


Telomere_length against rfMRI connectivity (ICA100 edge 808)

Date: 22 April, 2022


Results from two sample MR:

method nsnp b se pval
MR Egger 23 -0.1678632 0.1070199 0.1317050
Weighted median 23 -0.0070069 0.0594602 0.9061934
Inverse variance weighted 23 -0.0378202 0.0425299 0.3738627
Simple mode 23 -0.0130808 0.0953462 0.8921266
Weighted mode 23 -0.0048594 0.0777950 0.9507571

Heterogeneity tests

method Q Q_df Q_pval
MR Egger 24.13923 21 0.2863614
Inverse variance weighted 26.14254 22 0.2456125

Test for directional horizontal pleiotropy

egger_intercept se pval
0.007986 0.0060493 0.2009961

Test that the exposure is upstream of the outcome

snp_r2.exposure snp_r2.outcome correct_causal_direction steiger_pval
0.0357937 0.0008206 TRUE 0

Note - R2 values are approximate


Forest plot of single SNP MR

plot of chunk chunk5


Comparison of results using different MR methods

plot of chunk chunk6


Funnel plot

plot of chunk chunk7


Leave-one-out sensitivity analysis

plot of chunk chunk8