Two sample MR report
Telomere_length against rfMRI connectivity (ICA100 edge 577)
Date: 22 April, 2022
Results from two sample MR:
| method |
nsnp |
b |
se |
pval |
| MR Egger |
23 |
-0.0134721 |
0.1147990 |
0.9076950 |
| Weighted median |
23 |
-0.0089811 |
0.0573205 |
0.8754957 |
| Inverse variance weighted |
23 |
0.0051929 |
0.0438710 |
0.9057772 |
| Simple mode |
23 |
0.0962810 |
0.1160585 |
0.4156820 |
| Weighted mode |
23 |
-0.0365310 |
0.0860314 |
0.6752352 |
Heterogeneity tests
| method |
Q |
Q_df |
Q_pval |
| MR Egger |
27.77572 |
21 |
0.1466275 |
| Inverse variance weighted |
27.81699 |
22 |
0.1818258 |
Test for directional horizontal pleiotropy
| egger_intercept |
se |
pval |
| 0.0011462 |
0.006489 |
0.861484 |
Test that the exposure is upstream of the outcome
| snp_r2.exposure |
snp_r2.outcome |
correct_causal_direction |
steiger_pval |
| 0.0357937 |
0.0008434 |
TRUE |
0 |
Note - R2 values are approximate
Forest plot of single SNP MR

Comparison of results using different MR methods

Funnel plot

Leave-one-out sensitivity analysis