Two sample MR report


Telomere_length against rfMRI connectivity (ICA100 edge 368)

Date: 22 April, 2022


Results from two sample MR:

method nsnp b se pval
MR Egger 23 -0.1275241 0.0998190 0.2153506
Weighted median 23 -0.0091919 0.0577234 0.8734799
Inverse variance weighted 23 -0.0072127 0.0390155 0.8533336
Simple mode 23 0.1240585 0.1101656 0.2722543
Weighted mode 23 0.0158998 0.0808102 0.8458261

Heterogeneity tests

method Q Q_df Q_pval
MR Egger 19.70345 21 0.5401086
Inverse variance weighted 21.41814 22 0.4950406

Test for directional horizontal pleiotropy

egger_intercept se pval
0.0073884 0.0056423 0.2045235

Test that the exposure is upstream of the outcome

snp_r2.exposure snp_r2.outcome correct_causal_direction steiger_pval
0.0357937 0.0006501 TRUE 0

Note - R2 values are approximate


Forest plot of single SNP MR

plot of chunk chunk5


Comparison of results using different MR methods

plot of chunk chunk6


Funnel plot

plot of chunk chunk7


Leave-one-out sensitivity analysis

plot of chunk chunk8