Two sample MR report
Telomere_length against rfMRI amplitudes (ICA100 node 17)
Date: 22 April, 2022
Results from two sample MR:
| method |
nsnp |
b |
se |
pval |
| MR Egger |
23 |
-0.0584263 |
0.1042846 |
0.5812321 |
| Weighted median |
23 |
-0.0861389 |
0.0578374 |
0.1364005 |
| Inverse variance weighted |
23 |
-0.0341442 |
0.0398840 |
0.3919491 |
| Simple mode |
23 |
-0.1213004 |
0.1128302 |
0.2939927 |
| Weighted mode |
23 |
-0.1027617 |
0.0753265 |
0.1862939 |
Heterogeneity tests
| method |
Q |
Q_df |
Q_pval |
| MR Egger |
22.92083 |
21 |
0.3482141 |
| Inverse variance weighted |
22.99068 |
22 |
0.4022562 |
Test for directional horizontal pleiotropy
| egger_intercept |
se |
pval |
| 0.0014912 |
0.0058947 |
0.8027535 |
Test that the exposure is upstream of the outcome
| snp_r2.exposure |
snp_r2.outcome |
correct_causal_direction |
steiger_pval |
| 0.0357937 |
0.0007199 |
TRUE |
0 |
Note - R2 values are approximate
Forest plot of single SNP MR

Comparison of results using different MR methods

Funnel plot