Two sample MR report


Telomere_length against IDP dMRI TBSS FA External capsule R

Date: 23 April, 2022


Results from two sample MR:

method nsnp b se pval
MR Egger 23 -0.1235240 0.1225419 0.3249219
Weighted median 23 -0.0936560 0.0565118 0.0974622
Inverse variance weighted 23 -0.1531728 0.0468660 0.0010819
Simple mode 23 -0.0857157 0.0865927 0.3329992
Weighted mode 23 -0.0893590 0.0599925 0.1505520

Heterogeneity tests

method Q Q_df Q_pval
MR Egger 31.29256 21 0.0689250
Inverse variance weighted 31.39551 22 0.0883019

Test for directional horizontal pleiotropy

egger_intercept se pval
-0.0018206 0.0069262 0.7952257

Test that the exposure is upstream of the outcome

snp_r2.exposure snp_r2.outcome correct_causal_direction steiger_pval
0.0357937 0.0014129 TRUE 0

Note - R2 values are approximate


Forest plot of single SNP MR

plot of chunk chunk5


Comparison of results using different MR methods

plot of chunk chunk6


Funnel plot

plot of chunk chunk7


Leave-one-out sensitivity analysis

plot of chunk chunk8