Two sample MR report


Telomere_length against BA-exvivo lh volume BA3a

Date: 22 April, 2022


Results from two sample MR:

method nsnp b se pval
MR Egger 23 -0.1709691 0.1338266 0.2153545
Weighted median 23 -0.0395583 0.0604282 0.5127035
Inverse variance weighted 23 -0.0519036 0.0522177 0.3202295
Simple mode 23 -0.1083142 0.1106541 0.3382945
Weighted mode 23 -0.0502527 0.0708003 0.4852959

Heterogeneity tests

method Q Q_df Q_pval
MR Egger 38.06090 21 0.0126784
Inverse variance weighted 39.75412 22 0.0115492

Test for directional horizontal pleiotropy

egger_intercept se pval
0.0073106 0.0075636 0.3447677

Test that the exposure is upstream of the outcome

snp_r2.exposure snp_r2.outcome correct_causal_direction steiger_pval
0.0357937 0.0012587 TRUE 0

Note - R2 values are approximate


Forest plot of single SNP MR

plot of chunk chunk5


Comparison of results using different MR methods

plot of chunk chunk6


Funnel plot

plot of chunk chunk7


Leave-one-out sensitivity analysis

plot of chunk chunk8